Fider: Cross-tenant authentication bypass via email verification key

CVE-2026-65840Critical 9.6

← All vulnerabilities

Summary

In Fider's multi-tenant mode (HOST_MODE=multi), the lookup of email verification keys does not check the tenant. An attacker with any account on one tenant can use a sign-in verification key from that tenant to sign in as the same email address on another tenant. If that address is an administrator on the other tenant, the attacker gets full administrative access; otherwise a new account is created under that address. Single-host deployments (HOST_MODE=single, the default) are not affected.

Affected

  • Fider versions before 0.36.0 running with HOST_MODE=multi
  • Single-host deployments (HOST_MODE=single) are not affected

Fixed in

  • Fider 0.36.0

Workaround

  • Unknown. No vendor-documented workaround for multi-tenant mode was found. Upgrading is the fix.

Exploitation

  • No evidence of exploitation in the wild was found.
  • No public proof-of-concept was found in research. This does not prove that none exists.
  • Not checked against the CISA KEV catalog.

Our recommendation

  • Check whether any Fider instance runs with HOST_MODE=multi.
  • Upgrade such instances to 0.36.0 or later, preferably the latest release.
  • If a multi-tenant instance was exposed before the upgrade, review logs for unexpected sign-ins across tenants.
  • Single-host installations need no action for this CVE.

Public exploits

PoC-in-GitHub, Metasploit and Exploit-DB list nothing for this CVE.

Research sources

Researched and written up in English and German by an AI (Claude by Anthropic) based on NVD, CISA, EPSS and the sources listed. The vendor information is authoritative. Researched on 11 Nov 2026, 20:20.

Original description (NVD)

Fider is a feedback portal for feature requests and suggestions. Prior to version 0.36.0, in multi-tenant mode (HOST_MODE=multi), an attacker can use an email verification key issued by Tenant A to authenticate as the same email address on Tenant B. This completely bypasses tenant isolation and allows unauthorized account takeover across tenants. Single-host deployments (HOST_MODE=single, the default) are NOT affected. This issue has been patched in version 0.36.0.