IT SBIT Services
Schneeberger
DEEN
CVE tracker

TOTOLINK X2000R: Stack-based buffer overflow in boa formUploadFile

CVE-2026-9817Critical 9.1

← All vulnerabilities

Summary

A stack-based buffer overflow in the formUploadFile function of the boa web server on the TOTOLINK X2000R router allows arbitrary code execution. An attacker must first authenticate to the web administration interface and then send a specially crafted HTTP request. Successful exploitation gives the attacker control over the device, and the CVSS score is 9.1 (critical).

Affected

  • TOTOLINK X2000R, firmware TOTOLINK-X2000R-Gh-V1.0.0-B20250421.1327

Fixed in

Unknown. No vendor fix or fixed firmware version had been published at the time of writing.

Workaround

No vendor workaround is published. General measures:

  • Disable WAN and remote management.
  • Keep the web administration interface on the LAN only.
  • Change the default administrator credentials.

Exploitation

  • CISA SSVC: exploitation none, automatable no.
  • No public proof of concept found at the time of writing.
  • Not listed as known exploited.

Our recommendation

  • Inventory all TOTOLINK X2000R devices and check whether the web administration interface is reachable from the internet or from untrusted networks.
  • Restrict access to the admin interface and disable remote management until a fix is available.
  • Replace default credentials and monitor the TOTOLINK support site for firmware for this model; apply the fix promptly once it is released.

Public exploits

PoC-in-GitHub, Metasploit and Exploit-DB list nothing for this CVE.

Research sources

Researched and written up in English and German by an AI (Claude by Anthropic) based on NVD, CISA, EPSS and the sources listed. The vendor information is authoritative. Researched on 31 Oct 2026, 05:54.

Original description (NVD)

A stack-based buffer overflow vulnerability exists in the boa formUploadFile functionality of X2000R (version(s): TOTOLINK-X2000R-Gh-V1.0.0-B20250421.1327). A specially crafted HTTP request can lead to arbitrary code execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.

NVD references (1)

Sources

The tracker combines official, freely usable data sources – updated continuously:

This product uses data from the NVD API but is not endorsed or certified by the NVD. EPSS data © FIRST.org.

Affected? We can help.

We check whether your systems are affected, install updates and close the gap – continuously with the System Health Checker if you wish.