Netgate pfSense CE: OS command injection via wireless parent interface name

CVE-2026-111215High 8.6

← All vulnerabilities

Summary

Netgate pfSense CE through version 2.9.0 contains an OS command injection vulnerability in the wireless interface handling. An authenticated user with limited Wireless Edit or Interface Assignments privileges can submit a crafted parent interface name, which is passed unescaped into an ifconfig shell command. Successful exploitation allows commands to run as root on the firewall, giving full control of the device.

Affected

  • Netgate pfSense CE through 2.9.0 (CVE description; Plus edition not stated)
  • Vulnerable code: interface_wireless_clone(), reached via interfaces_wireless_edit.php and interfaces_assign.php

Fixed in

Unknown. No vendor advisory or fixed version found. Do not assume any CE 2.9.x build is patched.

Workaround

  • Restrict web GUI access to a management network or trusted IP addresses
  • Remove Wireless Edit and Interface Assignments privileges from users who do not need them
  • Disable wireless interfaces if they are not in use
  • Audit existing wireless interface names for shell metacharacters

Exploitation

  • Requires valid authentication with specific delegated privileges (CVSS PR:H)
  • Public PoC status unclear: VulDB states no exploit exists; two GitHub repositories are listed as references but have not been reviewed
  • CISA SSVC: exploitation PoC, not automatable
  • No evidence of exploitation in the wild found; CISA KEV status not checked

Our recommendation

  • Restrict GUI access to management networks and check whether the GUI is reachable from the internet
  • Review accounts and remove unnecessary Wireless and Interface Assignment privileges
  • Monitor for vendor advisories and apply the fixed release as soon as Netgate publishes one
  • Plan to patch together with the sibling issue CVE-2026-111214 (QinQ interface editing)
  • Review administrator accounts and monitor for unexpected interface configuration changes

Public exploits

PoC-in-GitHub, Metasploit and Exploit-DB list nothing for this CVE.

Research sources

Researched and written up in English and German by an AI (Claude by Anthropic) based on NVD, CISA, EPSS and the sources listed. The vendor information is authoritative. Researched on 1 Nov 2026, 08:04.

Original description (NVD)

Netgate pfSense CE through 2.9.0 contains an OS command injection vulnerability that allows authenticated users to execute commands as root by supplying a crafted wireless parent interface name. Attackers with limited Wireless Edit or Interface Assignments privileges can submit values like ath0;<cmd> via interfaces_wireless_edit.php or interfaces_assign.php, which interface_wireless_clone() interpolates unescaped into an ifconfig shell command.

NVD references (7)

Sources

The tracker combines official, freely usable data sources – updated continuously:

This product uses data from the NVD API but is not endorsed or certified by the NVD. EPSS data © FIRST.org.

Affected? We can help.

We check whether your systems are affected, install updates and close the gap – continuously with the System Health Checker if you wish.